EA2-B0-26-615-22A-DF [Carling Technologies]
Magnetic Circuit Breaker,;型号: | EA2-B0-26-615-22A-DF |
厂家: | Carling Technologies |
描述: | Magnetic Circuit Breaker, 电路保护 |
文件: | 总13页 (文件大小:1948K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
E
E-Se
-Series
rie
s
CIRCUIT BREAKER
The E-Series hydraulic-magnetic circuit breaker is ideally suited for higher current and voltage applications. It is
UL listed and CSA certified for branch circuit protection, which does not require a fuse back up. It is also UL
recognized and CSA certified as a supplementary protector and as a manual motor controller.
Its physical features include front and back mounting, screw and stud terminals and heavy duty box wire
connectors for solid wire or a pressure plate connector for standard wire. The E-series is available with handle
actuators and can be configured as .1-125 amps, up to 600VAC or 125VDC, with choice of time delays, actuator
colors and 1 to 6 poles configuration. Additionally, a Power Selector device is also available.
Resources:
Configure a Complete Part
Download CAD & Sales Drawing
Product Highlights:
•ꢀ ULꢀlistedꢀandꢀCSAꢀcertified
•ꢀ Certifiedꢀforꢀcircuitꢀbranchꢀprotection
•ꢀ Recognizedꢀasꢀaꢀsupplementaryꢀprotector
ꢀ andꢀasꢀaꢀmanualꢀmotorꢀcontroller
Typical Applications:
•ꢀ HighꢀVoltageꢀ/ꢀHighꢀCurrentꢀApplications
•ꢀ RenewableꢀEnergy
•ꢀ Military
•ꢀ IndustrialꢀControls
•ꢀ Generators
•ꢀ Optionalꢀpowerꢀselectorꢀdevice
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com
Application Support: team2@carlingtech.com
Phone: 860.793.9281 Fax: 860.793.9231
www.carlingtech.com
|
2
E-Series Circuit Breaker – General Specifications
Electrical
Mechanical
Maximum Voltage
600VAC 50/60 Hz, 125VDC (See
Table A)
Standard current coils: 0.100,
0.250, 0.500, 1.00, 2.50, 5.00,
7.50, 10.0, 15.0, 20.0, 25.0, 30.0,
50.0, 60.0, 70.0 & 100 Amp.
Endurance
10,000 ON-OFF operations @ 6
per minute; with rated Current and
Voltage.
All E-Series Circuit Breakers will
trip on overload, even when
Handle is forcibly held in the ON
position.
The operating Handle moves
positively to the OFF position
when an overload causes the
breaker to trip.
Current Ratings
Trip Free
Auxiliary Switch Rating SPDT; 10.1A 250VAC, 1.0A
65VDC; 0.5A 80VDC, 0.1A 125VAC
(with gold contacts).
Trip Indication
Insulation Resistance
Minimum of 100 Megohms at 500
VDC.
Dielectric Strength
UL, CSA: 2200 V 50/60 Hz for one
minute between all electrically
isolated terminals. E-Series Circuit
Breakers comply with the 8mm
spacing and 3750V 50/60 Hz
dielectric requirements from
hazardous voltage to operator
accessible surfaces, between
adjacent poles and from main
circuits to auxiliary circuits per
Publications EN 60950 and VDE
0805.
Physical
Number of Poles
Mounting
1 - 6
A 3” minimum spacing must be
provided between the circuit
breaker arc venting area on back
connected E-Series circuit
breakers and grounded
obstructions. E-Series circuit
breakers must be mounted on a
vertical surface.
Connectors, Box Type Front connected E-Series circuit
breakers are supplied with box
type pressure connectors that
Resistance, Impedance Values from Line to Load Terminal
- based on Series Trip Circuit
Breaker.
accept copper or aluminum
conductors as follows: 1/0-14
Copper, 1/0-12 Aluminum.
Internal Circuit
Configuration
Series and Switch Only, (with or
without auxiliary switch). Shunt
with current coils.
CURRENT
(AMPS)
TOLERANCE
(%)
0.10 - 5.0
5.1 - 20.0
20.1 - 50.0
15
25
35
Weight
Approximately 252 grams/pole
(Approximately 9 ounces/pole)
Housing-Black; Actuator - See
Ordering Scheme.
Standard Colors
Environmental
Designed in accordance with requirements of specification
MIL PRF-55629 & MIL-STD-202G as follows:
Shock
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition “I”.
Withstands 0.060” excursion from
10-55 Hz, and 10 Gs 55-500 Hz, at
rated current per Method 204C,
Test Condition A.
Pulse Tolerance Curves
Vibration
Time Delay Curves
62, 64 & 66
(100 Amps Max.)
Time Delay Curves
22, 24 & 26 (100 Amps Max.)
Moisture Resistance
Method 106D, i.e., ten 24-hour
cycles @ + 25°C to +65°C, 80-98%
RH.
Salt Spray
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Thermal Shock
Operating Temperature -40° C to +85° C
*Manufacturer reserves the right to change product specification without prior notice.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
3
E-Series Circuit Breaker – General Specifications
Electrical Tables
Table A: Lists UL Listed (489) & CSA Certified (C22.2 No. 5) configurations & performance capabilities as a Molded Case
Circuit Breaker.
E SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS
VOLTAGE
INTERRUPTING
CAPACITY (AMPS)
CURRENT RATING
FULL LOAD AMPS
HIGH
INTERRUPTING
CAPACITY
(AMPS)
CIRCUIT
CONFIGURATION
MAX.
RATING
FREQUENCY
PHASE
WITHOUT BACKUP
FUSE
80
125
DC
---
---
---
1
0.10 - 100
0.10 - 100
0.10 - 125
0.10 - 125
0.10 - 30
31 - 100
5,000
5,000
10,000
10,000
5,000
5,000
5,000
5,000
10,000
5,000
50,000
10,000
---
DC
125
DC
120
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
---
SERIES
240
1
10,000
240
1
120 / 240
120 / 240
120 / 240
240
1
0.10 - 30
31 - 100
10,000
---
1
1
101 - 125
0.10 - 100
---
3
---
Table B: Lists UL Recognized & CSA Accepted configurations & performance capabilities as a Component Supplementary
Protector.
E -SERIES TABLE B: COMPONENT SUPPLEMENTARY PROTECTORS
VOLTAGE
CURRENT RATING
SHORT CIRCUIT CAPACITY (AMPS)
UL/CSA
APPLICATION CODES
CIRCUIT
CONFIGURATION
MAX.
RATING
FULL LOAD
AMPS
GENERAL
PURPOSE AMPS
FREQUENCY
PHASE
UL
CSA
WITH BACKUP
FUSE3
WITHOUT
BACKUP FUSE
125
125
DC
DC
---
---
---
---
---
1
0.02 - 100
---
---
101 - 120
0.02 - 125
---
---
---
5,000
5,000
5,000
5,000
5,000
5,000
5,000
---
TC1,2, OL1, U1 TC1,2, OL1, U1
TC1,2, OL0, U1 TC1,2, OL0, U1
TC1, OL0, U3 TC1, OL0, U3
TC1,2, OL1, U1 TC1,2, OL1, U1
TC1,2, OL1, U1 TC1,2, OL1, U1
TC1,2, OL0, U1 TC1,2, OL0, U1
TC1,2, OL1, U1 TC1,2, OL1, U1
TC1,2, OL1, C1 TC1,2, OL1, C1
TC1,2, OL1, U1 TC1,2, OL1, U1
TC1,2, OL1, C1 TC1,2, OL1, C1
TC1,2, OL1, C1 TC1,2, OL1, C1
TC1,2, OL1, C1 TC1,2, OL1, C1
TC1,2, OL1, C1 TC1,2, OL1, C1
TC1, OL0, U3 TC1, OL0, U3
150
DC
---
---
160
DC
0.02 - 100
0.02 - 100
---
---
150 / 300
120 / 240
240
DC
---
---
SERIES &
SHUNT
50 / 60
50 / 60
50 / 60
0.02 - 100
---
---
1
0.02 - 100
0.02 - 100
---
250
1
---
10,000
---
5,000
---
277
50 / 60
1
0.02 - 100
---
10,000
10,000
10,000
10,000
---
480
50 / 60
50 / 60
50 / 60
DC
1 & 3
1 & 3
1 & 3
---
0.02 - 100
0.02 - 50
0.02 - 100
---
---
---
---
480 1
600
---
---
---
600 2
125
160
240
277
480
600
0.02 - 125
5,000
DC
---
0.02 - 120
0.02 - 100
0.02 - 100
0.02 - 100
0.02 - 100
0.02 - 100
DC
---
SWITCH
ONLY
50 / 60
50 / 60
50 / 60
50 / 60
1
1
1 & 3
1 & 3
Notes:
1
2
3
Per pole opposite polarity rating - Delta Configuration.
4 Poles connected in series
Requires branch circuit backup with a UL Listed Type K5 or RK5 fuse rated 15A minimum
and no more than 4 times full load amp rating and not to exceed 225A.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
4
E-Series Circuit Breaker – General Specifications
Electrical Tables
Table C: Lists UL Recognized, CSA Accepted and VDE Certified configurations and performance capabilities as a
Component Supplementary Protector.
E -SERIES TABLE C: COMPONENT SUPPLEMENTARY PROTECTORS WITH VDE
VOLTAGE
CURRENT RATING
SHORT CIRCUIT CAPACITY (AMPS)
UL/CSA VDE (Icn)
APPLICATION CODES
CIRCUIT
CONFIGURATION
MAX.
RATING
CONSTRUCTION NOTES
WITHOUT
BACKUP
FUSE
WITHOUT
BACKUP
FUSE
FREQUENCY PHASE FULL LOAD AMPS
UL
CSA
WITH BACKUP
FUSE1
125
240
DC
---
0.1 - 100
0.1 - 100
---
5,000
5,000
TC1,2, OL1, U1 TC1,2, OL1, U1
1 or 2 Poles
1 - 5 Poles. Up to 4
SERIES &
SHUNT
50 / 60
1 & 3
---
5,000
5,000
TC1,2, OL1, U1 TC1,2, OL1, U1 Current Poles, 1 Voltage
Pole
2 - 5 Poles. Up to 4
TC1,2, OL1, C1 TC1,2, OL1, C1 Current Poles, 1 Voltage
Pole
415
50 / 60
1 & 3
0.1 - 100
10,000
---
4,000
---
125
240
415
DC
0.1 - 125
0.1 - 100
0.1 - 100
SWITCH ONLY
50 / 60
50 / 60
1 & 3
1 & 3
Notes:
1
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum
and no more than 4 times full load amp rating and not to exceed 225 amps.
Table D: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for
Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft
Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors.
E SERIES TABLE D : UL1500 (Marine Ignition Protection)
VOLTAGE
SHORT CIRCUIT
CAPACITY (AMPS)
CURRENT RATING
FULL LOAD AMPS
APPLICATION CODES
CIRCUIT
CONFIGURATION
MAX.
RATING
FREQUENCY
PHASE
WITHOUT BACKUP
FUSE
UL
CSA
65
DC
---
1
0.02 - 100
0.02 - 100
0.02 - 100
5,000
1,500
1,500
TC1,2,OL1,U1 TC1,2,OL1,U1
TC1,2,OL1,U1 TC1,2,OL1,U1
TC1,2,OL1,U1 TC1,2,OL1,U1
SERIES
125
250
50 / 60
50 / 60
1
Agency Certifications
Component Supplementary
Protector (Class 3215 30, File
047848 0 000)
UL Recognized
UL Standard 1077
CSA Accepted
Component Recognition Program
as Protectors, Supplementary
(Guide QVNU2, File E75596)
CSA Standard C22.2 No. 235
Component Recognition Program
as Manual Motor Controls (Guide
NLRV2, File E135367)
Circuit Breaker Molded Case
(Class 1432 01, File 093910),
CSA Standard C22.2 No. 5.1 - M
CSA Certified
TUV Certified
VDE Certified
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
EN60934 under License No.
R72031056
UL Standard 1500
EN60934, VDE 0642 under File
No. 10537
UL Listed
UL Standard 489
Circuit Breakers, Molded Case
(Guide DIVQ, File E129899)
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
5
E-Series Circuit Breaker - UL 1077 – Ordering Scheme
E A 2 B 0 24 450 1 2 A C B
8
9
10
Mounting/
Barriers
11
12
Agency
1
2
3
4
5
6
7
Terminal
Actuator
Color
Maximum
Series
Actuator
Poles
Circuit
Auxiliary
Switch
Frequency
& Delay
Current Rating
Application Approval
Rating
12
8 TERMINAL
1 SERIES
BACK CONNECTED (FRONT MOUNTED ONLY)
MAX. RATING
E
9
9
9
1
10-32 Stud (All Terminals)
1/4-20 Stud (All Terminals)
M5 Stud (Line & Load)
M6 Stud (Line & Load)
50 A
120 A
50 A
2
A
B
2 ACTUATOR
9
100 A
A
Handle, one per pole
FRONT CONNECTED (BACK MOUNTED ONLY)
MAX. RATING
10
1
3
Box Wire Connector (Line & Load)
100 A
3 POLES
11
C
4
Box Wire Connector with Pressure Plate (Line & Load)
10-32 Screw (Line & Load)
100 A
50 A
50 A
50 A
50 A
1
One
Two
3
4
Three
Four
5
6
Five
Six
2
D
5
M5 Screw (Line & Load)
10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load)
M5 “Bus-Type” Screw (Line), 10-32 Screw (Load)
2
E
6
F
4 CIRCUIT
10
11
3
10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A
10-32 “Bus-Type” Screw (Line), Box Wire Connector
(
)
(
)
A
B
C
D
Switch Only no coil
E
F
G
Shunt Trip voltage
(
)
(
)
Series Trip current
Relay Trip current
with Pressure Plate (Load)
100 A
100 A
100 A
100 A
100 A
(
)
(
)
Series Trip voltage
Relay Trip voltage
7
1/4-20 Screw (Line & Load)
(
)
Shunt Trip current
G
8
M6 Screw (Line & Load)
1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load)
M6 “Bus-Type” Screw (Line), M6 Screw (Load)
4
H
9
5 AUXILIARY SWITCH
10
11
1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A
1/4-20 “Bus-Type” Screw (Line), Box Wire Connector
0
2
3
4
without Auxiliary Switch
6
7
S.P.S.T. 0.110 Q.C. Terminals
S.P.S.T. 0.110 Q.C. Terminals
(Gold Contacts)
S.P.S.T. 0.187 Q.C. Terminals
S.P.D.T. 0.187 Q.C. Terminals
J
S.P.D.T. 0.110 Q.C. Terminals
S.P.D.T. 0.139 Solder Lug
S.P.D.T. 0.110 Q.C. Terminals
(Gold Contacts)
with Pressure Plate (Load)
100 A
8
9
13
9 ACTUATOR COLOR & LEGEND
Actuator Color
White
Black
Red
Green
Blue
Yellow
Gray
Orange
I-O
A
C
F
H
K
M
P
ON-OFF
Dual
Legend Color
Black
White
White
White
White
Black
Black
Black
6 FREQUENCY & DELAY
B
D
G
J
1
2
3
4
5
6
7
8
3
03 DC 50/60Hz, Switch Only
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
5
10 DC Instantaneous
12 DC Short
14 DC Medium
16 DC Long
62 50/60Hz Short, High-inrush
64 50/60Hz Medium, High-inrush
66 50/60Hz Long, High-inrush
72 DC, Short,High-inrush
74 DC,Medium, High-inrush
76 DC, Long, High-inrush
L
5
N
Q
S
20 50/60Hz Instantaneous
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
R
6
6
6
92 DC, 50/60Hz Short, High-inrush
30 DC, 50/60Hz Instantaneous
32 DC, 50/60Hz Short
94 DC, 50/60Hz Medium, High-inrush
96 DC, 50/60Hz Long, High-inrush
10 MOUNTING / BARRIERS
BACK CONNECTED (FRONT MOUNTED ONLY)
Mounting Inserts
7
7 CURRENT RATING (AMPERES)
CODE AMPERES
A
B
6-32
ISO M3
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
090 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
660 60.000
670 70.000
680 80.000
690 90.000
810 100.000
811 110.000
812 120.000
14
FRONT CONNECTED (BACK MOUNTED ONLY)
Back Mounting Foot Type Front Mounting Inserts (Optional Use)
C
D
E
F
Short
Short
Long
Long
6-32
ISO M3
6-32
ISO M3
15
11 MAXIMUM APPLICATION RATING
16
16
16
16
A
B
C
D
E
F
65 VDC, 120 A
G
H
J
L
T
600 VAC, 100 A
125 VDC, 120 A
120/240 VAC, 100 A
240 VAC, 100 A
277/480 VAC, 100 A
277 VAC, 100 A
480 VAC, 100 A
415 VAC, 100 A
160 VDC, 100 A
16
125 VDC/240 VAC, 100 A
125 VDC/415 VAC, 100 A
16
W
12 AGENCY APPROVAL
B
D
UL 1077 / UL508 Recognized & CSA Accepted
UL 1077 Recognized, CSA Accepted, & VDE Certified
8
912 125.000
5
OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS)
4
5
Auxiliary Switch available on Switch Only and Series Trip units. On multi-pole units, only
one auxiliary switch is normally supplied mounted in the extreme right pole. Back mounted
units require special mounting provisions when auxiliary switch is specified. VDE approval
on Auxilary Switch Codes 0,2,3 & 4 only.
Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay
Codes 10 & 20. Series Trip construction with a voltage coil s VDE approved only if tied to
a protected pole.
Frequency & Delay Codes 92,94 & 96 are not VDE Certified.
Current Coil Ratings 0.100 - 100 ams are VDE Certified.
A06 6 DC, 5 DC
A12 12 DC, 10 DC
A18 18 DC, 15 DC
A24 24 DC, 20 DC
A32 32 DC, 25 DC
A48 48 DC, 40 DC
A65 65 DC, 55 DC
J48 48 AC, 40 AC
B25 125 DC, 100 DC J65 65 AC, 55 AC
J06 6 AC, 5 AC
K20 120 AC, 65 AC
L40 240 AC, 130 AC
J12 12 AC, 10 AC
J18 18 AC, 15 AC
J24 24 AC, 20 AC
6
7
8
9
125 A rating (Code 912) available as a Switch Only (Circuit Code A), rated 125 VDC (Code B).
An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 (Terminal
Code 1). 1/4-20 (Code 2), M5 (Code A), and M6 (Code B) terminals per UL requirement.
Notes:
1
VDE approval on 1-5 poles only. Standard multi-pole units identical poles except when
specifying auxiliary switch - (see Note 4). For mixed ratings, consult factory.
Switch Only & Series Trip construction available with either front or back connected
terminals.
Shunt construction available with back connected terminals, (Terminal Codes 1 & 2) only.
Circuit Codes B,C & D are VDE approved.
Switch Only construction: 30 amps or less select Current Rating Code 630; 31-70 amps,
select Current Rating code 670; 71-100 amps, select Current Rating Code 810; 101-125
amps Select Current Rating Code 912. Switch Only is VDE approved only if tied to a
protected pole.
10 Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG.
aluminum wire.
11 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details.
12 Terminal Codes A,B,D,E,G & H are not VDE Certified.
2
13 VDE approvals require Dual (I-O, ON-OFF) or I-O markings on all handles.
14 Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting
inserts normally supplied. However, terminal connections must be made prior to mounting.
15 Application ratings B,D,J,T & W are available with VDE.
3
16 415, 480 & 600 VAC ratings require 3 or 4 pole break 3Ø and 2 pole break 1Ø.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
6
E-Series Circuit Breaker - UL 489 – Ordering Scheme
24
1 2 A
E A 2 B 0
C C
Application Approval
Rating
450
8
9
10
Mounting/
Barriers
11
Maximum
12
Agency
6
1
2
3
4
5
7
Terminal
Actuator
Color
Frequency
& Delay
Series
Actuator
Poles
Circuit
Auxiliary
Switch
Current Rating
7
8 TERMINAL
1 SERIES
E
BACK CONNECTED (FRONT MOUNTED ONLY)
MAX. RATING
50 A
8
8
1
2
10-32 Stud (All Terminals)
1/4-20 Stud (All Terminals)
125 A
2 ACTUATOR
FRONT CONNECTED (BACK MOUNTED ONLY)
MAX. RATING
A
Handle, one per pole
9
10
3
C
4
5
6
F
Box Wire Connector (Line & Load)
100 A
Box Wire Connector with Pressure Plate (Line & Load)
10-32 Screw (Line & Load)
100 A
50 A
50 A
1
3 POLES
10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load)
1
2
One
Two
3
4
Three
Four
5
6
Five
Six
9
10
10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A
10-32 “Bus-Type” Screw (Line), Box Wire Connector
with Pressure Plate (Load)
100 A
125 A
100 A
2
7
8
9
J
1/4-20 Screw (Line & Load)
4 CIRCUIT
1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load)
( )
Series Trip current
Series Trip voltage
B
C
9
10
3
1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A
1/4-20 “Bus-Type” Screw (Line), Box Wire Connector
(
)
with Pressure Plate (Load)
100 A
4
5 AUXILIARY SWITCH
0
2
3
4
without Auxiliary Switch
6
7
S.P.S.T. 0.110 Q.C. Terminals
S.P.S.T. 0.110 Q.C. Terminals
(Gold Contacts)
12
9 ACTUATOR COLOR & LEGEND
S.P.D.T. 0.110 Q.C. Terminals
S.P.D.T. 0.139 Solder Lug
S.P.D.T. 0.110 Q.C. Terminals
(Gold Contacts)
Actuator Color
White
Black
Red
Green
Blue
ON-OFF Dual
Legend Color
Black
White
White
White
White
Black
Black
Black
8
9
S.P.S.T. 0.187 Q.C. Terminals
S.P.D.T. 0.187 Q.C. Terminals
B
D
G
J
1
2
3
4
5
6
7
8
6 FREQUENCY & DELAY
L
5
10
12
14
16
20
22
24
26
DC Instantaneous
DC Short
62 50/60Hz Short, High-inrush
64 50/60Hz Medium, High-inrush
66 50/60Hz Long, High-inrush
72 DC, Short,High-inrush
74 DC,Medium, High-inrush
76 DC, Long, High-inrush
Yellow
Gray
Orange
N
Q
S
DC Medium
DC Long
5
50/60Hz Instantaneous
50/60Hz Short
50/60Hz Medium
50/60Hz Long
10 MOUNTING / BARRIERS
BACK CONNECTED (FRONT MOUNTED ONLY)
Mounting Inserts
A
B
6-32
7
ISO M3
7 CURRENT RATING (AMPERES)
CODE AMPERES
11
FRONT CONNECTED (BACK MOUNTED ONLY)
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
090 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
660 60.000
670 70.000
680 80.000
690 90.000
810 100.000
811 110.000
812 120.000
Back Mounting Foot Type Front Mounting Inserts (Optional Use)
C
D
E
F
Short
Short
Long
Long
6-32
ISO M3
6-32
ISO M3
11 MAXIMUM APPLICATION RATING
1
120 VAC
B
C
D
125 VDC
13
120/240 VAC, 100 A
240 VAC, 100 A
12 AGENCY APPROVAL
C
F
UL 489 Listed & CSA Certified
UL 489 Listed, CSA Certified, & VDE Certified
8
Notes:
912 125.000
1
Standard multi-pole units identical poles except when specifying auxiliary switch -
(see Note 4). For mixed ratings, consult factory. VDE Certification on 1-5 poles only.
Series Trip construction available with either front or back connected terminals.
Series Trip construction with a voltage coil is not available as a single pole unit and must be
tied to a protected pole.
On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme
right pole per Figure A. Back mounted units require special mounting provisions when
auxiliary switch is specified. VDE Certification on auxilary switch codes 0, 2, 3 & 4 only.
Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay
Codes 10 & 20.
5
OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS)
2
3
A06 6 DC, 5 DC
A12 12 DC, 10 DC
A18 18 DC, 15 DC
A24 24 DC, 20 DC
A32 32 DC, 25 DC
A48 48 DC, 40 DC
A65 65 DC, 55 DC
J48 48 AC, 40 AC
B25 125 DC, 100 DC J65 65 AC, 55 AC
J06 6 AC, 5 AC
K20 120 AC, 65 AC
L40 240 AC, 130 AC
4
J12 12 AC, 10 AC
J18 18 AC, 15 AC
J24 24 AC, 20 AC
5
6
7
8
Frequency & Delay Codes 92, 94 & 96 are not VDE Certified.
Current Ratings under 0.100 amps are not VDE Certified .
An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 Stud
(Terminal Code 1) or 1/4-20 Stud (Code 2) terminals per UL requirement.
Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG.
aluminum wire.
9
10 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details.
11 Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting
inserts normally supplied. However, terminal connections must be made prior to mounting.
12 VDE Certification requires dual (I-O , ON-OFF) markings on all handles.
13 Not available with VDE Certification.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
7
E-Series Circuit Breaker – Circuit & Terminal Diagrams
Circuit & Terminal Diagrams: in. [mm]
Notes:
1
2
3
4
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
0-50 amps: 10-32 & M5 Studs .625±.062/15.88±1.574 long.
51-120 amps: 1/4-20 & M6 Studs .750±.062/19.05±1.574 long.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
8
E-Series Circuit Breaker – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
1/4 -20 stud terminal in Series Trip circuit configuration shown.
A 3” min spacing must be provided between the circuit breaker arc venting area
of back connected E-Series circuit breaker and grounded obstructions.
All dimensions are in inches [millimeters].
3
4
5
Tolerance ±.020 [.51] unless otherwise specified.
Circuit breakers must be mounted on vertical surface.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
9
E-Series Circuit Breaker – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
3
4
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Box wire connector terminal in Series Trip circuit configuration shown.
Circuit breakers must be mounted on vertical surface.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
10
Time Delay Values – E-Series Circuit Breaker
NOTES
Delay Curves 10,20,30: Breakers to hold 100% and must trip at 150% of rated current and greater wthin the time limit shown in these curves.
Delay Curves 12,14,16,22,24,26,62,64,66,72,74,76: Breakers to hold 100% and must trip at 125% of rated current and greater wthin the time limit shown in these curves.
Delay Curves 32,34,36,92,94,96: Breakers to hold 100% and must trip at 135% of rated current and greater wthin the time limit shown in these curves.
All curves: Data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading: Breakers are mounted in standard wall-mount position.
The minimum inrush pulse tolerance handling capacity on the above standard delays is 16 times rated current &20 times rated current for high inrush delays based on a 60Hz 1/2 cycle, 8.33 ms pulse.
AC
DC
Instantaneous
PERCENT OF RATED CURRENT
PERCENT OF RATED CURRENT
Short
PERCENT OF RATED CURRENT
PERCENT OF RATED CURRENT
Medium
PERCENT OF RATED CURRENT
PERCENT OF RATED CURRENT
Long
PERCENT OF RATED CURRENT
PERCENT OF RATED CURRENT
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
11
Time Delay Values – E-Series Circuit Breaker
AC/DC
Instantaneous
PERCENT OF RATED CURRENT
Short
PERCENT OF RATED CURRENT
Medium
PERCENT OF RATED CURRENT
Long
PERCENT OF RATED CURRENT
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
12
Sales Representatives, Distributors & Company Profile
Authorized Sales Representatives and Distributors
Click on a region of the map below to find your local representatives and distributors or visit
www.carlingtech.com/findarep.
CANADA
EUROPE
USA
MIDDLE
EAST
MEXICO
AFRICA
ASIA-PACIFIC
OCEANIA
SOUTH
AMERICA
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
@
Email: sales carlingtech.com
@
Northern Region Sales Office: nrsm carlingtech.com
@
Southeast Region Sales Office: sersm carlingtech.com
@
Midwest Region Sales Office: mrsm carlingtech.com
@
West Region Sales Office: wrsm carlingtech.com
@
Latin America Sales Office: larsm carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Suite 1607, 16/F Tower 2, The Gateway,
Harbour City, 25 Canton Road,
Tsimshatsui, Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
@
Email: sales carlingtech.com.hk
@
Shenzhen, China: shenzhen carlingtech.com
@
Shanghai, China: shanghai carlingtech.com
@
Pune, India: india carlingtech.com
@
Kaohsiung, Taiwan: taiwan carlingtech.com
@
Yokohama, Japan: japan carlingtech.com
|
|
Europe Middle East Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
@
Email: ltd.sales carlingtech.com
@
Germany: gmbh carlingtech.com
@
France: sas carlingtech.com
www.carlingtech.com
REV_01_2019